WebInterface issue

Support, Questions and Discussions on WinSyslog

Moderator: alorbach

WebInterface issue

Postby Guest » Wed Dec 03, 2003 10:34 pm

I have recently installed winsyslog. I have it running on mySQL DB however I recive the following error when I try to use the web interface:

HTTP 500.100 - Internal Server Error - ASP error
Internet Information Services

--------------------------------------------------------------------------------

Technical Information (for support personnel)

Error Type:
Microsoft VBScript runtime (0x800A000D)
Type mismatch: 'session'
/websyslog/EventsOnline.asp, line 18


Browser Type:
Mozilla/4.0 (compatible; MSIE 6.0; Windows NT 5.0)

Page:
GET /websyslog/EventsOnline.asp

Time:
Wednesday, December 03, 2003, 1:23:32 PM


More information:

Any help would be great thanks.

Omar
Guest
 

Postby Guest » Thu Dec 04, 2003 11:34 am

Dear Omar,

I have provided a link below. Please follow it and this should solve your problem.

http://www.winsyslog.com/Common/en/FAQ/ ... played.asp

Tamsila Siddique.
Adiscon.
Guest
 

Postby Guest » Thu Dec 04, 2003 5:43 pm

I followed the link and verfied all my field names and the table name. They are all correct but I am still recieving the same error message.
Guest
 

Postby mmeckelein » Thu Dec 04, 2003 10:36 pm

Hello Omar,

it seems that you have not enabled Session on your web server! Please enable sessions in your IIS configuration:

- right click the default web site
- select Home Directory
- select Configuration
- select App Options
- enable session state

I hope this solve the problem.
mmeckelein
Adiscon Support
 
Posts: 176
Joined: Wed Mar 12, 2003 12:07 pm

Postby Guest » Mon Dec 08, 2003 6:08 pm

Thank you. That did the trick.
Guest
 